Diagnostic Information

2-82

4059-XXX

3

Stepper Motor Level 1

Check the stepper motor connector
to ensure it is correctly installed at J4
on the output expander option board.
Go to

“Output Expander Control

Board - Level 1 Stepper Motor” on
page 5-22

. If correct, disconnect J4

from the option board and check the
resistance of the stepper motor at
J4:

J4-1 to J4-2: Approximately 10 ohms

J4-3 to J4-4: Approximately 10
ohms.

Also check each winding for shorts
between J4-1 thru J4-4 and the
motor housing. If you find a problem,
replace the stepper motor. If you do
not find a problem, replace the
output expander mechanical linkage
assembly.

FRU

Action