Lexmark 4059-XXX User Manual

Page 96

Advertising
background image

2-69

4059 Service Manual

4059-XXX

The elevator moves in one direction only.

FRU

Action

1

Stepper Motor
High Capacity Feeder
Option Control Board

Check the voltages at J1 on the high
capacity system board. The voltage
measures as follows:

static (motor connected)

J1-1 (Orange) +24 V dc
J1-2 (Yellow) +24 V dc
J1-3 (Green) +24 V dc
J1-4 (White) +24 V dc

motor running

J1-1 (Orange) approximately +12 V dc
J1-2 (Yellow) approximately +12 V dc
J1-3 (Green) approximately +12 V d
J1-4 (White) approximately +12 V dc

If any of the voltages are incorrect,
disconnect the motor and measure the
resistance between pin J1-1 to J1-3 and J1-
2 and J1-4. The resistance measures
between 10 and 15 ohms. If incorrect,
replace the motor. If correct, replace the
high capacity feeder control board.