Accessories – Lincoln Electric IDEALARC IM10018-A User Manual

Page 26

Advertising
background image

C-3

ACCESSORIES

C-3

12. Connect stick or air/carbon arc electrode and work

cable. See Figure C.2.

• Insert the electrode and work cables through the

strain relief loop on the right side (facing the front
of the machine) of the IDEALARC® DC-600 VRD.

• Connect the electrode cable to the "Positive" ter-

minal on the right side of the MULTI-PROCESS
SWITCH.

• Connect the work cable to the "Negative" terminal

on the right side of the MULTI-PROCESS
SWITCH.

NOTE: The instructions above are for connecting
the stick polarity positive. To change the polarity,
turn the IDEALARC® DC-600 VRD OFF, and
reverse the cables.

NOTE: When it is not necessary to have separate
ground cables for stick and semi-automatic or
automatic welding, connect a jumper from the
MULTI-PROCESS SWITCH "Work" terminal to
the MULTI-PROCESS SWITCH "negative" termi-
nal. See Figure C.2.

To operate the MULTI-PROCESS SWITCH, refer to
the operating instructions on the switch nameplate.

CONNECTIONS FOR SEMI-AUTO-
MATIC OR AUTOMATIC WIRE FEED-
ER CONTROL

1. Set the IDEALARC® DC-600 VRD ON/OFF

switch to OFF.

2. Set

the

IDEALARC®

DC-600

VRD

LOCAL/REMOTE switch to REMOTE.

3. Set the IDEALARC® DC-600 VRD OUTPUT TER-

MINALS switch to REMOTE.

4. Set the IDEALARC® DC-600 VRD MODE switch

to the welding process being used.

5. Refer to the proper connection diagram in the DIA-

GRAMS section for more information.

IDEALARC® DC-600 VRD

Advertising