E-5

TROUbLESHOOTING

E-5

IDEALARC® DC-600 VRD

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

If all recommended possible areas
of possible cause have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.

PRObLEMS
(SYMPTOMS)

Machine input contactor operates
but machine has no weld
output.Fan runs and pilot light
glows.

Red and Green lights do not come
on for approximately 5 seconds
when switching to or powering up
in CC mode.

Both red and green lights stay on
in CC mode well past the 5 second
pretest time.

POSSIbLE
CAUSE

1. Place OUTPUT TERMINAL

Switch to “ON”, or install a
jumper from #2 to #4 on
machine terminal strip. If
machine weld output is
restored the problem is in the
wire feeder or control cable.

2. If remote control is not being

used make certain the
LOCAL/REMOTE SWITCH
(SW3) is in the "Local" position.

3. Check 42V Circuit Breaker in

the front panel. Reset if neces-
sary.

4. Check for loose or faulty weld

cable connections.

5. Trigger circuit not working.

6. If machine functions properly in

CV modes but not in CC mode,
check for loose connections at
VRD P.C. board.

1. Check for faulty mode switch.

2. Check for loose connections at

VRD P.C. board.

3. Possible bad VRD P.C. Board.

1. Check to make sure output is

not shorted (electrode touching
work).

2. If using an across the arc Wire

Feeder, remove the clamp from
the output stud until after the 5
second pretest is complete.

3. Uncoil output cables.

RECOMMENDED
COURSE OF ACTION

OUTPUT PRObLEMS

Observe all Safety Guidelines detailed throughout this manual