Troubleshooting, Caution – Lincoln Electric IDEALARC IM10018-A User Manual

Page 33

Advertising
background image

E-6

TROUbLESHOOTING

E-6

IDEALARC® DC-600 VRD

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

If all recommended possible areas
of possible cause have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.

PRObLEMS
(SYMPTOMS)

Machine has maximum weld out-
put and no control.

VRD passes self test and green
light is on, but machine will not
Weld.

POSSIbLE
CAUSE

1. LOCAL/REMOTE Switch (S3)

in wrong position.

2. LOCAL/REMOTE Switch (S3)

is faulty, or an open lead going
to the LOCAL/REMOTE Switch
(S3).

1. Too much cable inductance.

• Uncoil output cables, shorten

cable length, or wrap work and
electrode cables together.

2. Too much cable.

• Maximum cable length (work

and electrode) is approximately
300 feet.

3. Buildup on stick electrode.

Clean or replace electrode.

4. Possible shorted bridge rectifier,

if pilot light is off.

5. Fault detected after self test.

Cycle power to reset machine.

RECOMMENDED
COURSE OF ACTION

OUTPUT PRObLEMS

Observe all Safety Guidelines detailed throughout this manual