E-4

TROUbLESHOOTING

E-4

IDEALARC® DC-600 VRD

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PRObLEMS
(SYMPTOMS)

Input contactor (CR1) chatters.

Variable or sluggish welding arc.

Output Control Pot. not functioning
in “LOCAL” control.

No output control in “REMOTE”
control.

115VAC duplex receptacle not
working. (60HZ machines only)

POSSIbLE
CAUSE

1. The input line voltage may be

low. Check all three phases.

2. Make sure input line voltage

matches machine rating and
the reconnect panel is connect-
ed correctly for the line voltage.

1. Poor electrode or work lead con-

nection.

2. Welding cables too small.

3. Welding current or voltage too

low.

1. LOCAL/REMOTE Switch (S3)

faulty or in wrong position.

2. Faulty OUTPUT CONTROL Pot.

1. LOCAL/REMOTE Switch (S3)

faulty or in wrong position.

2. Faulty Remote Control Unit.

1. 115VAC Circuit Breaker tripped.

RECOMMENDED
COURSE OF ACTION

OUTPUT PRObLEMS

If all recommended possible areas
of possible cause have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.