0 flue options – Potthof & Co Potterton Gold HE Range Condensing Combination Boiler 33kw User Manual

Page 22

Advertising
background image

22

© Baxi Heating UK Ltd 2012

8.0 Flue Options

Vertical Flues
(Twin Pipe)

(ii)

(i)

Vertical
Flues

(ii)

(i)

The total equivalent

length for this example

is = 6.5 metres.

1m extension

135°bend

91.5°bend

1m

0.25m

0.5m

5
2
2

5.0m
0.5m
1.0m

AIR DUCT

N

o

of

fittings/pipes

Sub total

Equivalent

Length Value

Equivalent Length Air Duct = 6.5m

1m extension

135°bend

91.5°bend

1m

0.25m

0.5m

5
2
2

5.0m
0.5m
1.0m

FLUE DUCT

N

o

of

fittings/pipes

Sub total

Equivalent

Length Value

Equivalent Length Flue Duct = 6.5m

(ii)

(i)

C

Roof

Terminal

A

B

This bend is equivalent to

1 metre

Total Equivalent Length =

A+B+C+1x90°Bend

All vertical and angled runs must be included,

measured from the boiler adaptor (point X) to the

joint with the flue terminal (point Y). One 91.5°

bend or two 135° bends can be included without

reduction of the flue length.

If further elbows are required the flue length must

be reduced by the following amounts:-

1 metre for each 91.5° bend

0.5 metre for each 135° bend

8.2

Twin & Vertical Flue Systems

1. Maximum permissible equivalent flue lengths are:-

(60/100)

(80/125)

Vertical Concentric

10 metres

20 metres

Vertical Twin Pipe

15 metres

2. Any additional “in line” bends in the flue system must be
taken into consideration.
Their equivalent lengths are:-
Concentric Pipes:

135° bend

0.5 metres

93° bend

1.0 metres

Twin Flue Pipe

135° bend

0.25 metres

91.5° bend

0.50 metres

The elbow supplied with the standard horizontal telescopic
flue kit is not included in any equivalent length calculations

NOTE: Flue length is measured from point (i) to (ii) as
shown.

IMPORTANT: All flue systems must be securely
supported at least once every metre. Suitable
pipe supports are available as accessories.

1m Min to

15m Max

120mm Min

apart

Y

600mm Min

apart

T

1m Min

to

15m Max

Mini Terminal
on Air Duct
(sited in loft)

Q