0 changing components – Potthof & Co Potterton Gold HE Range Condensing Combination Boiler 33kw User Manual

Page 42

Advertising
background image

42

14.0 Changing Components

© Baxi Heating UK Ltd 2012

IMPORTANT: When changing components ensure that
both the gas and electrical supplies to the boiler are
isolated before any work is started. When the
component has been changed turn the selector switch
fully anticlockwise against the spring pressure to the
reset position and hold for 5 seconds to reset the boiler
before recommissioning.

See Section 13.2 “Annual Servicing” for removal of case
panel, door etc.

14.1

Igniter (Fig. 80)

1. Disconnect the igniter feed plug and the electrode leads,
noting their positions.

2. Undo the screw securing the bracket to the boiler.

3. Remove the igniter and transfer the bracket to the new
component.

4. Reassemble in reverse order.

14.2

Spark and Sensing Electrodes (Fig. 81)

1. Disconnect the electrode leads, noting their positions.

2. Remove the retaining screws securing each of the
electrodes to the combustion box cover and remove the
electrodes.

3. Check the condition of the sealing gasket and replace if
necessary. Reassemble in reverse order.

Fig. 80

Igniter

Igniter Feed

Plug

Electrode

Leads

Bracket

Fig. 81

Spark

Electrode

Sensing

Electrode

Electrode

Leads