0 changing components – Potthof & Co Potterton Gold HE Range Condensing Combination Boiler 33kw User Manual

Page 43

Advertising
background image

43

14.0 Changing Components

© Baxi Heating UK Ltd 2012

Cover

Gas Inlet

Fan

Venturi

Injector

Collector

Burner
Gasket

When fitting the venturi
ensure that the arrow is

pointing forward

Fig. 82

Fig. 83

Gas Inlet Pipe

Venturi

Injector

Fig. 84

14.3

Fan (Fig. 83)

1. Undo the nut on the gas inlet pipe to the venturi (Fig. 83)
and pull the sensing pipe off the fan.

2. Disconnect the electrode leads, noting their position and
disconnect the fan electrical plugs.

3. Undo the screws securing the collector to the cover (33
models) or extension piece (24 & 28 models).

4. Remove the collector and fan assembly, being careful to
retain the injector in the venturi.

5. Undo the screws securing the fan to the venturi and fit the
new fan, replacing the seal if necessary.

6. Examine the burner gasket and replace if necessary.

7. Reassemble in reverse order, ensuring that the injector is
in place and the sensing pipe is connected to the fan.

14.4

Venturi (Fig. 82)

1. Remove the collector and fan assembly as described in
section 14.3.

2. Extract the injector from the venturi.

3. Undo the screws securing the fan to the venturi and the
venturi to the collector.

IMPORTANT: When fitting the new venturi, ensure the
arrows on it’s base point into the collector (Fig. 84).

4. Examine the seals and burner gasket, replace if necessary.

5. Reassemble in reverse order, ensuring that the injector is
in place.

14.5

Injector (Fig. 82)

1. Remove the collector and fan assembly as described in
section 14.3.

2. Extract and replace the injector and reassemble in reverse
order.

Advertising