Specifications

A

-

4

CONTACT
CLOSURE Adjunct
Jack Specifications

Operates up to 150 feet (45.72 meters) from control unit using 24 gauge solid
conductor wire if 2 Contact Closures used; up to 800 feet (243.84 meters) from
control unit using 24 gauge solid conductor wire if only 1 Contact Closure used

Install the Contact Closure Adjunct in the same building as the control unit; cannot
be installed out-of-doors

Has three terminals per Contact Closure, providing a normally open and normally
closed function for each Contact Closure

Maximum contact voltages and current:

— 30 VAC, 1 Amp

— 50 VDC, 1 Amp

SMDR Output
Format

1200 baud

8 data bits

XON/XOFF protocol

Line feeds

No parity

2 stop bits

Carriage return

Environmental
Requirements-
Control Unit

Mount on a wall at least 2 feet (0.6 meters) from the floor (wall mounting required)

Locate within 5 feet (1.5 meters) of the network interface jacks and a properly
grounded electrical outlet not controlled by a switch, using supplied 7-foot
(2.1-meter) cords

Operating temperature 32° to + 104°F (0° to + 40°C), not in direct sunlight

Humidity 15%-90%, noncondensing

For proper ventilation and easy replacement of modules, provide the following
minimum clearance around the control unit:

— 5-Slot carrier: 1 foot (0.3 meter) clearance at the top and sides and 2 feet (0.6

meter) at the front and bottom

— 2-Slot carrier or Stand-alone ACS processor module: 1 foot (0.3 meter)

clearance at the front, top and right side, and 2 feet (0.6 meter) at the bottom and
left side

Locate in an area free of excess moisture, corrosive gases, dust, and chemicals

Electrical
Requirements-
Control Unit

U.S. and Canada: 90-264 VAC, 47-63 Hz, 3-prong outlet separate ground,
separately fused at 15 Amps

Other countries: 90-264 VAC (220 VAC fused at 10 Amps)

Grounding to comply with Underwriters Laboratories (UL) 1459:

A. An insulated grounding conductor that is not smaller in size and equivalent in

insulation material and thickness to the grounded and ungrounded branch circuit
supply conductors, except that it is green with or without one or more yellow
stripes, is to be installed as part of the circuit that supplies the product or system

B. The grounding conductor mentioned in item A is to be connected to ground at

the service equipment

C. The attachment-plug receptacles in the vicinity of the product or system are all

to be of a grounding type, and the grounding conductors serving these
receptacles are to be connected to earth ground at the service equipment