Error messages

(continued)

Warning messages

Priority

O

Monitor display

O

Description

O

VTR operation and corrective action

High

Low

E-01 (LOW RF)
This appears when envelope levels approximately
1/3 that of normal levels are detected for more than
one second during playback, recording, or editing.
VTR: Operation continues.

O

Clean the video heads.

E-02 (HIGH ERROR RATE)
This appears when the error rate has increased to
the extent that correction or interpolation was
performed on either the video or audio signals.
VTR: Operation continues.

O

Clean the video heads.

E-00 (SERVO NOT LOCKED)
This appears when the servo is not locked for three
or more seconds during playback, recording, or
editing.
VTR: Operation continues.

O

Check the tape.
A tape recorded other than PAL format may have
been inserted.

E-10 (FAN STOP)
This is displayed when the fan motor stops.
VTR: Operation continues.

O

Check that nothing is obstructing the fan
movement.

E-09 (NO RF)
This appears during playback when a blank section
(tape blank) lasting for one or more seconds has
been detected.
Such a section is identified as a tape blank when all
of the following conditions are met.

O

No head outputs

O

No playback data readout

O

No CTL (Excluding DV and DVCAM tapes)

VTR: Operation continues.

O

Check the tape.
A tape on which material has not been recorded
may have been inserted.