Set iochannel, Set iochannel mode, Set iochannel digital i/o – Perle Systems 5500208-41 User Manual

Page 79: Set iochannel digital input

Advertising
background image

79

Set IOChannel

Set IOChannel

Set IOChannel Mode

Description Sets general I/O channel settings for the specified channel, these settings are available

to all channels and I/O serial pins.

User Level Admin
Syntax

Options

i/o_channel

Specify the channel number, for example, d2 or a4. Temperature models use Analog
input, so the channel numbers are a1-a4.

mode

description

Set IOChannel Digital I/O

Description Sets up the Digital I/O channel to act as either an output or input channel.
User Level Admin
Syntax
Options

digital_channel

Specify the Digital channel number, for example, d2.

source-type

Set IOChannel Digital Input

set iochannel <i/o_channel> [mode enabled|disabled]

[description <string>]

Enables the channel, allowing the settings to become active.

Provide a description of the channel, making it easier to identify. The channel

description can be up to 20 characters.

set iochannel <digital_channel> source-type input|output

Specify whether the channel will drive the line (output) or will be reading the status of

the line (input). The default is

Input

. The internal jumpers must match the software

configuration, so if you change this setting to

Output

, you will have to also change the

internal hardware jumpers.

Description Sets the Digital input settings for the channel.
User Level Admin
Syntax

set iochannel <digital_channel>

[alarm [trigger disabled|inactive-input|active-input]
[clear auto|manual] [syslog on|off] [snmp on|off]]
[description <string>] [invert-signal on|off]
[latch disabled|inactive-to-active|active-to-inactive]

Options

digital_channel

Specify the Digital channel number, for example, d2.

alarm

Configures alarm settings when the Digital input trigger is activated.

Advertising