Set iochannel analog (true analog) – Perle Systems 5500208-41 User Manual

Page 84

Advertising
background image

Set IOChannel

84

IOLAN DS1/TS2 CLI Reference Guide, Version 4.1

Set IOChannel Analog (True Analog)

active-to-inactive-delay

When the I/O is commanded to an inactive state, this is the length of the delay before

the command is executed. Valid values are 1-9999 x 100 ms. The default is 100 ms.

inactive-to-active-delay

When the I/O is commanded to an active state, this is the length of the delay before the
command is executed. Valid values are 1-9999 x 100 ms. The default is 100 ms.

active-signal-width

How long the channel output will be active during the pulse mode. Valid values are

1-9999 x 100 ms. The default is 100 ms.

inactive-signal-width

How long the channel output will remain inactive during pulse mode. Valid values are

1-9999 x 100 ms. The default is 100 ms.

failsafe-action

When there has been no I/O activity within the specified time (set in the Global
Settings) and the

Failsafe Timer

is triggered, you can set the

Failsafe Action

to:

z

None—The state of the Digital/Relay output remains the same, no change.

z

Activate Output—Activates the output.

z

Deactivate Output—Deactivates the output.

Description Sets the Analog input channel settings.
User Level Admin
Syntax

set iochannel <analog_channel> type current|voltage

range <range_specifier>

set iochannel <analog_channel> alarm

[level 1|2|3|4|5 [mode on|off] [trigger-type disabled|low|high]
[trigger-level <decimal_value>] [clear-mode auto|manual]
[clear-level <decimal_value>] [snmp on|off] [syslog on|off]]

Options

analog_channel

Specify the Analog channel number, for example, a2 or a4 (this also applies to

Temperature models).

type

Select the type of input being measured, either

Current

or

Voltage

. The default is

Current

.

range

Select the range for the measurement type. For current, the range is:

z

0-20 (0-20mA) This is the default.

z

4-20 (04-20mA)

For voltage, the range is:

z

1 (+/-1V)

z

5 (+/-5V)

z

10 (+/-10V) This is the default.

z

150 (+/-150mV)

z

500 (+/-500mV)