Table of auto off error messages – Panasonic AJ-PD950 User Manual

Page 74

Advertising
background image

Table of AUTO OFF Error messages

Counter display

CAP ROTATE TOO
SLOW

CAP TENSION ERROR

CAP TENSION ERROR

DEW

DRUM ROTATE TOO
FAST

DRUM ROTATE TOO
SLOW

E-FF

FRONT LOAD ERROR

FRONT LOAD MOTOR

LOADING MOTOR

Monitor display

CAP ROTA TOO
SLOW

DEW

DRUM ROTA TOO
FAST

DRUM ROTA TOO

SLOW

E-FF

FRONT LOAD ERROR

FRONT LOAD MOTOR

LOADING MOTOR

Description

If the capstan motor speed is abnormally low, the

AUTO OFF lamp lights, and the message display
flashes.

If an abnormal tension at the supply side is detected
in the capstan mode, the AUTO OFF lamp lights, and

the message display flashes.

If condensation is detected, the AUTO OFF lamp
lights, the message display flashes, and the VTR is
transferred to the eject mode. After the tape is
ejected, the drum rotates in order to eliminate the
condensation.
When the condensation has been eliminated, the
AUTO OFF lamp and message display go off, and the
VTR can be used.
<Notes>

1) If condensation is detected in the eject mode, the

drum starts rotating as soon as it is detected.

2) If condensation is detected when the cassette has

been inserted, the drum rotation is stopped, and
after the tape is ejected, the drum starts rotating.

If the cylinder motor speed is abnormally high, the

AUTO OFF lamp lights, and the message display
flashes.

If the cylinder motor speed is abnormally low, the

AUTO OFF lamp lights, and the message display
flashes.

If the tape start and tape end are detected simulta-
neously either during or after loading, the AUTO OFF
lamp lights, and the message display flashes.

The AUTO OFF lamp lights and the message display
flashes when the take-up reel has been rotating idly
for a fixed period of time while the start/end

processing operation during loading (half position) is
being performed.

If the cassette does not move up even when 6

seconds have elapsed since the VTR was transferred
to the eject mode, the AUTO OFF lamp lights, and the

message display flashes.
<Note>

If the cassette does not move down inside the
machine even when 6 seconds have elapsed since

the cassette was inserted, the VTR is transferred to

the eject mode.

When the unloading operation is not completed within
6 seconds, the AUTO OFF lamp lights, and the
message display flashes.
<Note>
When the loading operation is not completed within 6
seconds, the VTR is transferred to the eject (unload-
ing) mode.

VTR operation

(Restart condition)

STOP
(POWER OFF

ON)

STOP
(POWER OFF

ON)

EJECT
(Normal operation
resumed after
condensation is
eliminated)

STOP
(POWER OFF

ON)

STOP

(POWER OFF

ON)

STOP

(POWER OFF

ON)

STOP

(POWER OFF

ON)

STOP

(POWER OFF

ON)

STOP

(POWER OFF

ON)

- 7 4 -

Advertising
This manual is related to the following products: