Rs-232c interface, Introduction, Hardware specifications – Panasonic AJ-PD950 User Manual

Page 76

Advertising
background image

RS-232C interface

1. Introduction

(1) The VTR can be operated by commands when the RS-232C interface is used.

(See command table on page 79 – 81.)

(2) Conditions for acknowledging commands from RS-232C interface

The front panel REMOTE/LOCAL switch must be at REMOTE.
The setup menu item No. 204 “RS232C SEL” must be ON.

If the above conditions are not met, [ACK] + [STX]ER001 [EXT] is returned to the external unit.

Whether the [ACK] code is returned depends on the setting which has been selected for setup menu item No. 209
“RETURN ACK”.

2. Hardware specifications

External interface specifications

1) Connector specifications

Connector: D-SUB 25-pin (crossover cable supported)

Pin No.

Signal

Circuit name

1

FG

Protective ground

2

RXD

Received data

3

TXD

Transmitted data

4

CTS

Clear to send

5

RTS

Request to send

6

DTR

Data terminal ready

7

SG

Signal ground

20

DSR

Data set ready

2) Example of connection with controller (PC)

Using crossover cable with D-SUB 25-pin
connectors

PC side
(D-SUB 25-pin

connector)

FG 1

TXD 2

RXD 3
RTS 4

CTS 5
DSR 6
SG 7
DTR 20

VTR side

1

FG

2

RXD

3

TXD

4

CTS

5

RTS

6

DTR

7

SG

20

DSR

Description

Frame ground

Data is sent to PC.

Data is received from PC.

Shorted with pin 5.

Shorted with pin 4.

No processing

Signal ground

+ voltage output after communication enable status

Using crossover cable with D-SUB O-pin and
25-pin connectors

PC side
(D-SUB 9-pin

connector)

RXD

2

TXD

3

DTR

4

SG

5

DSR

6

RTS

7

CTS

8

VTR side

1

FG

2

RXD

3

TXD

4

CTS

5

RTS

6

DTR

7

SG

20

DSR

- 7 6 -