Front panel bottom section, Controls and their functions – Panasonic AJ-PD950 User Manual

Page 14

Advertising
background image

Controls and their functions

(continued)

<Front Panel Bottom Section>

VIDEO IN LEVEL control and switch
These are used to adjust the video input level.

PRESET: When the switch is set to “PRESET”, the video input level is set to the unity

value (0 dB).

MANUAL: When the switch is set to “MANUAL”, the video input level can be adjusted

using this control.

VIDEO OUT LEVEL control and switch
When setup menu No. 00 (ENCODER SEL) is set to “LOCAL”, the video output level can
be adjusted.
When the switch is set to “PRESET”, the video output level is set to the unity value (0 dB).
When the switch is set to “MANUAL”, the video output level can be adjusted using this control.

CHROMA LEVEL control and switch
When setup menu No. 00 (ENCODER SEL) is set to “LOCAL”, the chroma level can be
adjusted.
When the switch is set to “PRESET”, the chroma level is set to the unity value (0 dB).
When the switch is set to “MANUAL”, the chroma level can be adjusted using this control.

SETUP control and switch
When setup menu No. 00 (ENCODER SEL) is set to “LOCAL”, the setup level can be
adjusted.
When the switch is set to “PRESET”, the setup level is set to the unity value (0 IRE).
When the switch is set to “MANUAL”, the setup level can be adjusted using this control.

HUE control and switch

When setup menu No. 00 (ENCODER SEL) is set to “LOCAL”, the hue can be adjusted.
When the switch is set to “PRESET”, the hue is the unity value (0°).
When the switch is set to “MANUAL”, the hue can be adjusted using this control.

CF switch

This selects whether the playback framing is to be locked in 4-field or 8-field increments or
2-field increments.

* Applies only to

AJ-PD950

4F/8F: 525 mode: The framing is locked in 4-field increments.

625 mode: The framing is locked in 4- or 8-field increments. The framing can be

selected in either 4- or 8-field increments using setup menu No. 108

(CAP. LOCK).

2F:

The framing is locked in 2-field increments.

TC generator switch

REGEN:

When the REGEN/PRESET switch is at REGEN, the internal time code

generator is synchronized with the time code which the time code reader

read from the tape. Whether to set TC or UB to REGEN can be selected at

the setup menu No. 503 (TCG REGEN).

PRESET:

When the REGEN/PRESET switch is at PRESET, presetting is enabled by
the controls on the operation panel or by remote control.

REC RUN:

The time code runs only during recording when the RUN MODE switch has

been set to REC. The time code runs constantly when the REGEN/PRESET

switch is set to REGEN.

FREE RUN: The time code runs regardless of the operation mode as long as the power is

being supplied when the RUN MODE switch has been set to FREE.

- 1 4 -

Advertising
This manual is related to the following products: