Premier Floors User Manual

Page 43

Advertising
background image

43

Panel Core

thickness

deflection

Panel

span (ft.)

4’

8’

10’

12’

14’

16’

18’

20’

22’

24’

9 1/4”

L/360

274

188*

116

100

80

58

47

36

32

28

L/240

326*

188*

147*

134*

120

90

70

52

46

41

L/180

326*

188*

147*

134*

121*

108*

93

68

61

53

11 1/4”

L/360

327*

188*

167*

140

116

90

75

57

47

36

L/240

327*

188*

167*

153*

132*

110*

97*

83*

69

53

L/180

327*

188*

167*

153*

132*

110*

97*

83*

83*

70

* indicates ultimate load divided b

y 3 for the design capacity

.

2X’

s are Hem-F

ir #2 or equivalent.

4’ span is a minimum two span condition.

Panels require a minimum of 1-1/2” bearing

.

Lumber splines are spaced 4’ o.c.

Floor panels should ha

ve a 3/4” minimum top skin or a 7/16” top skin o

ver

la

yed with 7/16” finish flooring per

pendicular to the panels.

More infor

mation on this char

t can be found in T

echnical Bulletin #19 (www

.pbssips.com).

Refer to T

echnical Bulletin #21 for floor applications (www

.pbssips.com).

Maximum Roof Span

Maximum Floor Span

Advertising