Header

d

epth

d

eflection

Header

s

pan (ft.)

4’

6’

8’

10’

12”

L/480

345

243

156

99

L/360

450

295

190

125

L/240

630

382

236*

153*

18”

L/480

705

388

254

235

L/360

750*

482

302*

281*

L/240

750*

482

302*

281*

24”

L/480

698

582*

368*

350*

L/360

895*

582*

368*

350*

L/240

895*

582*

368*

350*

load Chart 8:
allowable Header loads (plf)
Condition 2–Panel is not Continuous
over opening (splines)

* indicates ultimate load divided b

y 3 for the design capacity

.

In all cases where a concentrated load is placed o

ver on opening or the design loads exceed the capacity of a

panel header

, Premier Insul-Beam II should be used if possible or an engineered header assembly is required.

More infor

mation on this char

t can be found in T

echnical Bulletin #10 (www

.pbssips.com).

SIPs wall panel
spline minimum
6” from edge
of opening

Advertising