Premier Floors User Manual

Page 46

Advertising
background image

46

load Chart 7:
allowable Header loads (plf)
Condition 1–Panel is Continuous
over opening (no splines)

Header

d

epth

d

eflection

Header

s

pan (ft.)

4’

6’

8’

10’

12”

L/480

740*

385*

229*

142*

L/360

740*

385*

229*

142*

L/240

740*

385*

229*

142*

18”

L/480

798*

574*

385*

311*

L/360

798*

574*

385*

311*

L/240

798*

574*

385*

311*

24”

L/480

886*

629*

429*

361*

L/360

886*

629*

429*

361*

L/240

886*

629*

429*

361*

* indicates ultimate load divided b

y 3 for the design capacity

.

In all cases where a concentrated load is placed o

ver on opening or the design loads exceed the capacity of a

panel header

, Premier Insul-Beam II should be used if possible or an engineered header assembly is required.

More infor

mation on this char

t can be found in T

echnical Bulletin #10 (www

.pbssips.com).

Continuous
over opening