Chapter Three: Hardware Installation and

Replacement

This chapter refers to installing or replacing options within the Clean Screen itself. Instructions
on installing the Clean Screen onto a standard Planar mounting option will come with the mount-
ing equipment itself.

Removing the Back Housing

Figure 8

Power down unit first and disconnect it from the power source.

1. Power down unit first and disconnect it from the power source.

2. Use a static-free workstation.

3. Place Clean Screen face down on a secure flat surface, using a cloth or other non-abrasive
material to protect the display.

4. Remove the twelve attachment screws from the back housing using a T25 torx driver.

5. Remove the three attachment screws from the back housing located near the connector ports
using a T15 torx driver.

6. Remove the back panel itself by gently lifting the bottom back edge first.

6

Planar Clean Screen PC User’s Manual

Twelve T25 Torx screws

Four holes for standard
Planar mounting options (

10

32

)

Three T15 Torx screws