Boot Failures

The System BIOS attempts to display an error message on the display and halts when it
encounters the following error conditions.

1. Fixed disk error

Causes:
• No drive connected
• Configured for 0 cylinders
• Controller reset failed
• Drive not ready
• Track 0 seek timed out
• Drive initialization failed
• Drive recalibration failed
• Last track seek failed

2. CMOS checksum failed

Causes:
• CMOS checksum failed

3. Timer error

Causes:
• System timer (0) failed

4. I/O error

Causes:
• I/O conflicts exist for serial and parallel ports, hard disk (any or all)

5. Over Temperature Error

Causes:
• Internal temperature exceeded 50˚C causing the system to shut down

6. Other error

Causes:
• Peripheral components IRQ conflicts

The System BIOS prints an error message but does not halt when it encounters the following
error conditions.

1. RTC error

Causes:
• RTC lost power

2. CMOS error

Causes:
• RTC battery failed

3. Configuration error

Causes:
• User BIOS Extension Region X will exceed DFFFFH