Limit Stops Menu

The manual pan limit stops can be set at the controller using the Limit Stops menu:

1. Program preset 95 (28). The main menu appears.

2. Position the cursor (>) beside Limit Stop.

3. Press the Iris Open button to enter the Limit Stop menu.

4. Move the cursor to Set Scan Limits and press the Iris Open button. PRESS IRIS OPEN TO SET LEFT LIMIT appears.

5. Move the pan and tilt to the desired left limit position and press the Iris Open button to set the left manual limit. PRESS IRIS OPEN TO SET

RIGHT LIMIT appears.

6. Move the pan and tilt to the desired right limit position and press the Iris Open button to set the right scan limit.

7. Exit the Limit Stop menu.

Clear Scan Limit Stops

To clear the scan limit stops:

1. Program preset 95 (28). The main menu appears.

2. Position the cursor (>) beside Limit Stop.

3. Press the Iris Open button to enter the Limit Stop menu.

4. Move the cursor to Clear Scan Limits and press the Iris Open button. The cursor will flash to an asterisk (*) briefly to indicate the limits have

been disabled.