RESET CAMERA

Resetting the camera returns the settings to their defaults.

Turning off power does not reset the camera. Camera settings are retained in memory. When the power is turned back on, the settings will be the
same as they were when the power was turned off.

To reset the camera:

1. Program preset 95 (28). The main menu appears.

2. Position the cursor (>) beside Camera.

3. Press the Iris Open button to enter the Camera menu.

4. Position the cursor (>) beside Reset Camera.

5. Press the Iris Open button to reset the camera.

Default Setting

Models

ES30PCBW24/
ES31PCBW24/

Models

ES30PC22/
ES31PC22/

Models

ES30PC16/
ES31PC16/

Backlight comp

Off

Off

Off

Zoom Limit

No default

No default

No default

Gain/AGC

Gain Limit

25

29

27

Auto iris

Mode
Level
Peak

NTSC

PAL

Auto

Auto

106

96

16

16

Auto

66
16

NTSC

PAL

Auto

Auto

66

57

8

16

Low light limit

2

2

N/A

Shutter speed

Auto

Auto

Auto

Auto focus mode

Auto

Auto

Auto

IR Filter

IR filter mode
Auto IR level

Auto
Dusk

N/A
N/A

N/A
N/A

Sharpness

Auto sharpness
Sharpness

On

No default

On

No default

On

No default

White balance

Auto white bal
R Gain
B Gain

On

No default
No default

On

No default
No default

On

No default
No default

Backlight comp

Off

Zoom limit

x- -

Reset camera
<Gain/AGC>
<Auto iris>
Next
Exit

Camera Menu

<Camera>
<Line Sync>
<Power Up>
<Wiper>
<Limit Stop>
<Alert>
<Other>
ACK Alert
Exit

MAIN MENU