Pressurized ioc – Pelco ESPRIT ES30PC User Manual

Page 62

Advertising
background image

62

C311M-N (6/06)

PRESSURIZED IOC

IMPORTANT: Disconnect power to the Esprit system before removing or installing the pressurized cartridge. Software conflicts can occur if the
Esprit is not powered-down before removing/installing the IOC.

There are no user-serviceable parts internal to the pressurized integrated optics cartridge. If vessel fails, Pelco recommends that it be returned to
the factory for replacement or repair.

Removing the IOC

1. Remove the 4 Phillips screws located on the outside viewing window.

2. Open hinge door to the system. Remove the cap screw that

secures the wiper board. Unplug the ribbon cable connector.

3. Lift up wiper board and unplug the cartridge power cables. Let board

dangle to the side of the enclosure.

4. Lift cartridge out of the enclosure.

RIBBON CABLE CONNECTOR

CAP SCREW

CARTRIDGE POWER
CABLE CONNECTORS

CARTRIDGE

Advertising