Appendix, Switch settings for sw1 – Pelco ESPRIT ES30PC User Manual

Page 63

Advertising
background image

C311M-N (6/06)

63

Appendix

NOTE: Esprit will sense and automatically select input from Coaxitron control signals in either the standard or extended mode. Therefore, the
DIP switch settings have no effect on Coaxitron control signals.

*SW1-3 is not used; set it in the OFF position.

*SW1-4 is not used; set it in the OFF position.

Table A. Switch Settings for SW1

Switch Setting

Baud Rate

SW1-1

SW1-2

SW1-3

2400

OFF

OFF

OFF*

4800

ON

OFF

OFF*

9600

OFF

ON

OFF*

Switch Setting

SW1-4

SW1-5

SW1-6

SW1-7

SW1-8

OFF*

Note (1)

Note (2)

Note (3)

Note (4)

NOTES:

(1)

SW1-5

OFF For controllers that have more than 32 presets.
ON For American Dynamics controllers (32 presets).

(2)

SW1-6

OFF For all control systems except CM9502 with variable speed keyboards. For CM9502 with

fixed speed keyboards, set switch OFF.

ON For CM9502 with variable speed keyboards to get smoother joystick control.

(3)

SW1-7

OFF RS-422 transmitter is not terminated.
ON RS-422 transmitter is terminated.

(4)

SW1-8

OFF 1.2 volt peak-to-peak video level.
ON 1 volt peak-to-peak video level.

Advertising