Accessories for hle and hlez, Longitudinal flange connection set (option v), Automation – Parker Hannifin 192-510011N7 User Manual

Page 30: Determining the chain length

Advertising
background image

Accessories for HLE and HLEZ

Automation

30

Parker Hannifin GmbH

Electromechanical Division

Highly flexible, thin lines with a low bending strength should be loosely gathered together and routed in order in a protective
hose. When selecting the size of the protective hose, ensure that its area is considerably greater than the sum of the individual
cross-sectional areas. As a guide, allow approximately 10 % of the diameter of each line as clearance.

Load diagrams

Maximum suspended length vs. additional load

Maximum length with permitted deflection vs. additional load

1

0

2

3

4

5

0

1

2

3

0.625

0.450

0.320

0

2

4

6

suspended length

L

f

in m

stroke L

S

in m

additional load q

z

in kg/m

L

S

L

f

0.625

0.450

0.320

0

1

2

3

0

2

4

6

0

1

2

3

4

5

Length with
deflection L

D

in m

Stroke L

S

in m

additional load q

z

in kg/m

L

D

L

S

KR

KR 52 94 150

4

8

KR 200

300

Determining the chain length

Suspended chain

Chain with permitted deflection

0.320: rounded to a multiple of 32 mm

0.320: rounded to a multiple of 32 mm

0.450: rounded to a multiple of 45 mm

0.450: rounded to a multiple of 45 mm

%

6

.

/

/

/





0.625: rounded to a multiple of 62.5 mm

%

6

.

/

.5

/

/







0.625: rounded to a multiple of 62.5 mm

Longitudinal flange connection set (option V)

Longitudinal flange plates make it possible to move more than the standard available stroke. A flange connection is always
necessary if the maximum travel path is exceeded (refer to Technical data, pages 6 and 20). Profile sections should normally
be split equally, with the separation point close to a fixing point. The bearing distance should generally be between 1.0m and
1.5m. If a longitudinal flange connection is used to extend the travel distance, the load data must be reduced as shown in the
table below. An HLE with a longitudinal flange connection should only be installed with the profile aperture in the top or the
bottom.

Unit

HLE80

HLE100

HLE150

HLEZ100

HLEZ150

maximum permitted load

N

0.5 x Fx

*1

0.5 x Fx

*1

0.5 x Fx

*1

Speed

m/s

< 1

< 1

< 1

Acceleration

m/s

2

< 1

< 1

< 1

Repeatability

mm

> ±0.5

> ±0.5

> ±0.5

unchanged

*1. Fx-HLE: refer to page 7;

A

A

Section A-A

FL

FB

HB

FD

Model / size

Type

FL

FB

FD

HB

HLE80

LVS80

300

70

15

80

HLE100 / HLEZ100

LVS100

400

90

15

100

HLE150 / HLEZ150

LVS150

500

130

15

150