Service replacement parts, Service and repairs, Troubleshooting guide – Porter-Cable N030679 User Manual

Page 29

Advertising
background image

29 - ENG

SERVICE

REpLACEmENT pARTS

Use only identical replacement parts. You can also order parts from your nearest

service center.

SERVICE AND REpAIRS

All quality tools will eventually require servicing and/or replacement of parts. All

repairs made by our service centers are fully guaranteed against defective material

and workmanship. We cannot guarantee repairs made or attempted by others.

TROUBLEShOOTING GUIDE

This section provides a list of the more frequently encountered malfunctions,

their causes and corrective actions. The operator or maintenance personnel can

perform some corrective actions, and others may require the assistance of a

qualified PORTER CABLE technician or your dealer.
problem

Code

Engine will not start ........................... 1, 2, 3, 4, 14, 15, 16, 17, 18, 19, 20, 21, 27
No electrical output ............................................................... 5, 6, 7, 8, 9, 10, 12, 13
NOTE: If there is still no power at the receptacles, Contact a Customer Care

Center.

Repeated main breaker tripping ......................................................................... 9, 10
Generator overheating ........................................................................................ 9, 11
Engine does not continue to run after starting ..1, 2, 3, 14, 16, 18, 19, 20, 21, 27
Knocking noise ....................................................................................................23
Over speed or low speed ....................................................................... 24, 25, 26
Low power ........................................................................................ 16, 19, 22, 23

CODE pOSSIBLE CAUSE

pOSSIBLE SOLUTION

1

Engine On/Off switch in OFF

position.

Turn to ON position

2

Choke in wrong position

Adjust choke accordingly

3

Fuel shut-off valve in closed

position

Open fuel shut-off valve

4

Unit loaded during start-up

Remove load from unit

5

Faulty receptacle

Contact a Customer Care Center.

6

Receptacle thermal circuit

breaker tripped

Depress and reset

7

Defective capacitor

Contact a Customer Care Center.

8

Faulty power cord

Repair or replace cord

9

Generator overloaded

Reduce load

10

Faulty cords or equipment

Check for damaged, bare or frayed

wires on equipment. Replace.

11

Insufficient ventilation

Move to adequate supply of fresh air

12

Faulty windings in stator

Contact a Customer Care Center.

13

Faulty wire harness

Contact a Customer Care Center.

14

Low or no fuel

Add fuel

15

Bad fuel

Drain fuel tank and replace with fresh,

clean, regular unleaded gasoline

with a minimum of 86 octane

16

Low oil

Add oil

Advertising