Bu 22 1, Al se 3, Al se 4 io 1 – Panasonic AG-TL950 User Manual

Page 26: Al se 2

Advertising
background image

26

4-7 Contents of Menu Switches

4 ON-SCREEN/MENU SWITCHES

[ ]: Factory setting • The lower section in the items and set values columns shows what’s on the VCR’s display.

Screens

Items

Set values

Function

AL/SENSOR

[OFF]

IN

ON

OFF

ON

Selects whether or not the buzzer sounds during alarm or sensor
recording.
OFF: The buzzer does not sound.
ON: The buzzer sounds.

BU 22 2

BU 22 3

ERR WARN

[OFF]
ON

OFF

ON

Sets whether or not the buzzer sounds when a warning occurs.
OFF: The buzzer does not sound.
ON: The buzzer sounds. When the warning is released, the buzzer

sound stops.

IN/OUT

CAMERA SW

[OFF]
1 FIELD
2 FIELD

OFF

1FRD

2FRD

Sets the camera switching signal output interval.
OFF:

No camera switching signal is output.

1 FIELD: Set to this position to switch cameras every 1 field. (However

1 frame when on 2H or 6H.)

2 FIELD: Set to this position to switch cameras every two fields (1

frame).

Sets whether or not the buzzer sounds when the tape ends in the Record mode.
OFF: The buzzer does not sound.
ON: The buzzer sounds when the tape ends during recording. Also, the buzzer

sounds when the tape reel counter value set with the menu switch <CNT
TAPE END> on the SRI/EXT MODE screen is reached.
When the mode is changed by pressing the [REW] button, [EJECT]
button or [OPERATE] button, the buzzer sound stops.

BUZZER

TAPE END

[OFF]
ON

OFF

ON

BU 22 1

OFF

STOP

DURATION

5 SEC
10 SEC
15 SEC
30 SEC
60 SEC
120 SEC
[180 SEC]
CONTINUE
MANUAL

5

..

.

180

CONT

nANU

ALARM/
SENSOR
MODE

Selects the recording duration for alarm or sensor recording.
5 — 180 SEC: Alarm or sensor recording is performed for the specified

time (5 sec. to 180 sec.)

CONTINUE: Alarm or sensor recording continues to the end of the tape.
MANUAL:

Alarm or sensor recording continues for as long as alarm
signals are input. Set to this position when specifying the
alarm recording time with a switcher.
*To ensure accurate alarm search and alarm scan operation,

be sure to set the recording time to 5 seconds or more.

TAPE END

[OFF]

MODE

STOP

Selects whether or not the Stop mode is forcibly engaged when the tape ends
even if there is an alarm or sensor recording.
OFF: The forced Stop mode is not engaged.

• When the tape ends, the mode set with the menu switch <AUTO

REW> or <REPEAT REC> on the <VTR MODE> screen is engaged.

STOP: The Forced Stop mode is engaged.

AL SE 3

(VCR's display)

AL SE 4

iO

1

REC T-MODE

[2H]
6H
L12H
L18H
L24H
24H
48H
NORMAL

2H

6H

L12H

L18H

L24H

24H

48H

NORn

Selects the recording mode for alarm or sensor recording.
(Refer to page 28.)

AL SE 2

Advertising