Maintenance and Troubleshooting 51

The printed colors do not match the screen. The colors of the label shown in PTPrint may not

match the original design program, other print programs or the printed output of the CX1200.

There are no

ICC profiles

available to make colors shown in PTPrint match the printed output or

other programs. The colors shown on screen will have no effect on the printers ability to print

specific CMYK values or Pantone Matched CMYK values.

Default Settings

NOT set. This error appears before printing or when the status monitor is

opened. Specific settings will be listed belowthe error message. This means that default settings

were changed via the printer control panel or through the print settings window before printing.

The message is a warning that the settings do not match defaults. If you do not change the settings

back to their original values unexpected errors may occur. Contact tech support if you have trouble

restoring the defaults.

9.7

Replacing the Fuser

1. Pull the tensioner forward until you are able to flip

the housing back out of the way of the printer doors.

2. Open both the upper right and the lower right

access doors.

Warning:

The fuser assembly may be hot. Let it cool

before continuing.

3. Pull down the green latches. They slide toward the

center to release the fuser.

4. Pull the fuser out, and set it on a clean, flat surface.

5. Insert a new fuser into the printer.

6. Slide the latches out, and then pull up to refasten them.

7. Close the doors.