Setting the line signaling for an isdn/pri line – Patton electronic 2996 User Manual

Page 44

Advertising
background image

Configuring the RAS with a Web browser

44

Model 2960/2996 RAS User Manual

3 • Configuring the RAS for operation

– dsx1D4 AT&T D4 format DS1

– For ISDN PRI service, set the line type to dsx1ESF

2. Click on the

Line Coding

pop-up menu (see

figure 29

on page 39). The most common options are:

dsx1B8ZS and dsx1AMI. For ISDN PRI service, set the line coding to dsx1B8ZS.

3. Click on the

Line Build Out

pop-up menu (see

figure 29

on page 39) and select t1pulse0dB(1).

4. Click on the

Yellow Alarm Format

pop-up menu and choose linkYellowFormatBit2(1).

5. Click on

Submit Query

.

At this point, the WAN front panel LEDs will become active. A solid green FRAME light indicator means that
the RAS has synchronized with the T1 line.

Note

If you suspect that there is a physical malfunction in the WAN ports,
you can assemble a loopback connector to test the port (see

figure 30

on page 40).

If you have an T1/PRI (ISDN) line, refer to “Setting the line signaling for an ISDN/PRI line”. Otherwise,
refer to “Setting the line signaling for a robbed-bit T1 line”.

Setting the line signaling for an ISDN/PRI line
Do the following:

1. Scroll down the

WAN Circuit Configuration

window, until the signaling Settings section appears (see

figure 31

on page 41).

2. Click on the

Signal Mode

pop-up menu and choose messageOriented(4).

3. Click on the

Message Oriented Switch Type

pop-up menu (see

figure 31

on page 41) and choose either

ni1(National ISDN 1), dms(Nortel Switch) or att(AT&T Customer).

4. Click on

Submit Query

.

Signaling is now configured for ISDN/PRI.

Setting the line signaling for a robbed-bit T1 line
Do the following:

1. Scroll down the

WAN Circuit Configuration

window, until the signaling Settings section appears (see

figure 31

on page 41).

2. Click on the

Signal Mode

pop-up menu and choose robbedBit(3).

3. Click on

Submit Query

.

4. Click on the

Robbed-Bit signaling Protocol

pop-up menu and choose LinkGroundStart, LinkLoopStart, or

LinkEMWinkStart.

5. Click on

Submit Query

.

6. Click on the

Yellow Alarm Format

pop-up menu and choose one of the following options:

– For T1 lines with D4/AMI settings, this should be set to linkYellowFormatBit(1).