85 – setting the time data, Locking the time code to an external source, External lock operation procedure – Panasonic AJ-D610WBp User Manual

Page 85: Example of connections for external locking

Advertising
background image

– 85 –

Setting the Time Data

Locking the Time Code to an External Source

The time code generator of the VTR section can be locked to an external generator.

Example of connections for external locking

Example 1: Locking the time code to an external signal

Example 2: When a multiple number of AJ-D610WB units are connected with one unit

serving as the master unit and the others as the slave units

Reference video signal

To the next unit

External Lock Operation Procedure

1

Set the POWER switch to ON.

2

Set the F-RUN/R-RUN switch to F-RUN.

3

Set the DISPLAY switch to TC.

4

Supply reference time code and reference video signals, whose phases correlate in a way
that meets the time code standards, to the TC IN and GENLOCK IN/(VIDEO IN) connectors,
respectively.

MASTER

SLAVE

SLAVE

CAM OUT

TC OUT

TC OUT

TC OUT

TC IN

TC IN

TC IN

GENLOCK

IN

GENLOCK

IN

GENLOCK

IN

CAM
OUT

CAM
OUT

2

3

1

GENLOCK IN

GENLOCK IN

TC OUT

TC IN

Reference
time code

Advertising