Register
Number

XVG/eXVG Parameter

Name

Write

Access

Description Type

Default

Value

3521 IDM_FLOWCTRLEN

W4

Flow Control Enable: 0=Baseline (Stroke
Mode) Valve, 1=FM / FC / FL valve

U16

1

3522 IDM_FLTTMCURRENT W4

Current fault persist time: x20mS, range 0-
32767

U16

32767

3523 IDM_FLTTMTMPSHUT W4

Over temperature shutdown fault persist time:
x20mS, range 0-32767

U16

500

3524

IDM_SOLIMAX

W4

Solenoid Current Limit: range 1-4095

U16

3500

3525 IDM_AO0CFG

W2

Analog Output Zero Configuration:
0=Disabled
1=Position Feedback (0-MaxStroke)
2=Measured Flow (0-Flow Range)
3=Corrected Output Pressure (0-500 PSIA)
4=Input Pressure (0-500 PSIA)
5=Output Pressure (0-500 PSIA)
6=Gas Temperature (-40 to 150 Deg. C)
7=Test mode to write directly to AO with
ADC gain/offset via IDM_AOUTx

U16 1

3526 IDM_AO1CFG

W2

Same as IDM_AO0CFG

U16

0

3527 IDM_AO2CFG

W2

Same as IDM_AO0CFG

U16

0

3528 IDM_SELFCALENABLE W4

Auto Zero Calibration Enable: 0=Disabled,
1=Enabled

U16 0

3529 IDM_DPENABLE

W4

Differential Pressure Measurement Enable (3
PSIA and higher):
0=show actual flow on all pressures except
reverse flow conditions.
1=pressure differential less than 3.0 PSIA
will report 0 PPH flow.

U16 1

3530 IDM_FLTTMPOS15V

W4

Positive 15V source fault persist time:
x20mS, range 0-32767

U16 3

3531 IDM_FLTTMNEG15V

W4

Negative 15V source fault persist time:
x20mS, range 0-32767

U16 3

3532 IDM_FLTTMTEMPAMB W4

Ambient/electronics fault persist time:
x20mS, range 0-32767

U16 50

3533 IDM_FLOWCALCURVE W4

Flow Calibration Curve, range 0 to 100

U16

0

3534 IDM_ELECTINTRFC

W4

Electrical interface configuration number,
range 0 to 3

U16 0

3535 IDM_FLANGEACC

W4

Flange

accessory configuration number,

range 0 to 3

U16 0

3536

IDM_LVDTEXSCALE

W4

LVDT excitation output scale factor. Re-tune
if IDM_LVDTPHASE not a multiple of 4.
Units of %. Range: 0 to 200

U16 100

3537 IDM_OCT

W4

Motor over-current threshold for AdvDiag
over-current event counter. Range: 0-4095

U16 3850

3538 IDM_CLTHRESH

W4

Communication lost fault threshold time,
units of seconds. Fault disabled if = 0.
Range: 0 to 500

U16 0

3539 IDM_DJSUMDB

W4

Demand jitter accumulator dead-band, units
of demand counts. Range: 0 to 200

U16 4

3540 IDM_SLAVEADDR

W2

Modbus slave (node) address.
Range: 1 to 247

U16 1