Hamilton Sundstrand Company Fuel Metering Valves XVG User Manual

Page 30

Advertising
background image

Register
Number

XVG/eXVG Parameters
Name

Write

Access

Description Type

5056 5057

IDM_OPS

RO

Histogram array parameter for OutletPressure,
seconds

U32

5058 5059

IDM_FS

RO

Histogram array parameter for flow measurement,
seconds

U32

5060 5061

IDM_MCS

RO

Histogram array parameter for MotorCurrent, seconds

U32

5062 5063

IDM_DJS

RO

Histogram array parameter for demand jitter, seconds
(command change accumulation/sec)

U32

7000 7001

IDM_POSININCHES

RO

Valve Position in inches

Float

7002 7003

IDM_INPUTPRES

W3

Input Pressure, PSIA

Float

7004 7005

IDM_OUTPUTPRES

W3

Output Pressure, PSIA

Float

7006 7007

IDM_OUTPCORRECT

RO

Output Pressure Corrected, PSIA

Float

7008 7009

IDM_MEASFLOW

RO

Measured Flow, PPH

Float

7010 7011

IDM_CDAOUT

RO

CdA specified by demand

Float

7012 7013

IDM_MEASUREDCDA

RO

Measured CdA, calculated from measured position

Float

7014 7015

IDM_GASTEMP

W3

Gas Temperature, degrees F (includes TEMPOFF)

Float

7016 7017

IDM_VOLTS3PT3

RO

3.3V supply voltage, Volts

Float

7018 7019

IDM_PRESSRATIO

RO Pressure

Ratio

Float

7020 7021

IDM_DMDININCHES

RO

Position Demand in inches

Float

7022 7023

IDM_FLOWLIMDMD

RO

Flow Limiting Demand Output

Float

7024 7025

IDM_MINFLOWLIM

RO

Calculated Min Flow Limit

Float

7026 7027

IDM_MAXFLOWLIM

RO

Calculated Max Flow Limit

Float

7028 7029

IDM_FLOWLIMRNG

RO

Calculated Flow Limiting Range

Float

7030 7031

IDM_FLOWRNGSCALR

RO

Flow Range Scaler, Max Flow / Max Counts

Float

7032 7033

IDM_SOLTEMP

RO

Solenoid Temperature, not used

Float

7034 7035

IDM_EQCONSTA

RO

Flow equation constant A

Float

7036 7037

IDM_EQCONSTB

RO

Flow equation constant B

Float

7038 7039

IDM_EQCONSTC

RO

Flow equation constant C

Float

7040 7041

IDM_EQCONSTD

RO

Flow equation constant D

Float

7042 7043

IDM_EQCONSTE

RO

Flow equation constant E

Float

7044 7045

IDM_EQCONSTF

RO

Flow equation constant F

Float

7046 7047

IDM_LVDTAPLUSB

RO

LVDT A+B signal

Float

7048 7049

IDM_LVDTAMINUSB

RO

LVDT A-B signal

Float

7050 7051

IDM_FVOLTS3PT3

RO

Fault Log, Volts3pt3 at time of fault

Float

7052 7053

IDM_FSOLTEMP

RO

Fault report variable, not used

Float

7054 7055

IDM_FINPUTPRES

RO

Fault Log, InputPres at time of fault

Float

7056 7057

IDM_FOUTPUTPRES

RO

Fault Log, OutputPres at time of fault

Float

7058 7059

IDM_FGASTEMP

RO

Fault Log, GasTemp at time of fault

Float

7060 7061

IDM_FFLOWRANGE

RO

Fault report variable, not used

Float

7062 7063

IDM_FMEASFLOW

RO

Fault Log, MeasFlow at time of fault

Float

7064 7065

IDM_FFAULTDATA

RO

Fault Log, Fault Data at time of fault

Float

7066 7067

IDM_FPOSININCHES

RO

Fault Log, PosInInches at time of fault

Float

7068 7069

IDM_FTEMPAMB

RO

Fault Log, TempAmb at time of fault

Float

7070 7071

IDM_FVOLTSPOS15

RO

Fault Log, VoltsPos15 at time of fault

Float

30