Hamilton Sundstrand Company Fuel Metering Valves XVG User Manual

Page 15

Advertising
background image

Register
Number

XVG/eXVG Parameter

Name

Write

Access

Description Type

Default

Value

5508 5509

IDM_SETUPCHECK

W4

Setup parameter checksum

U32

12345

5510 5511

IDM_SHUTDNFLTS

W4

Faults to Shutdown on, same as
IDM_FAULTFLAGS

U32

0

5512 5513

IDM_FAULTOUTCFGL

W4

Fault output configuration bit-field, to
configure which fault codes will show on
digital output channel 0. Same bits as
IDM_FAULTFLAGSL

U32

0

5514 5515

IDM_TAT

W4

Thermal age threshold for Electronics Age
Warning fault, units of seconds. Fault
disabled if = 0. Range: 0 to 4 billion

U32

0

5516 5517

IDM_TITHRESH

W4

Total inches traveled warning fault threshold,
units of inches. Fault disabled if = 0.
Range: 0 to 4 billion

U32

0

7500 7501

IDM_LVDTGAIN

W4

LVDT Gain: range 0.1 – 3.0

Float

1

7502 7503

IDM_LVDTOFFSET

W4

LVDT Offset: range -200 – 200

Float

0

7504 7505

IDM_ADCAGAIN

W4

ADC A Gain: range 0.1 – 3.0, obsolete

Float

1

7506 7507

IDM_ADCAOFFSET

W4

ADC A Offset: range -200 – 200, obsolete

Float

0

7508 7509

IDM_OUTPUTGAIN

W4

4-20mA Feedback Gain, Obsolete

Float

1

7510 7511

IDM_ADCBGAIN

W4

ADC B Gain: range 0.1 – 3.0, obsolete

Float

1

7512 7513

IDM_ADCBOFFSET

W4

ADC B Offset: range -200 – 200, obsolete

Float

0

7514 7515

IDM_DMD420GAIN

W4

4-20mA Demand Input Gain: (Obsolete)

Float

1.016

7516 7517

IDM_DMD420OFF

W4

4-20mA Demand Input Offset: (Obsolete)

Float

0

7518 7519

IDM_CONSTR

W0

R Gas Constant: must be non-zero, default is
Air

Float

53.34

7520 7521

IDM_CONSTK

W0

K Gas Constant: must be non-zero, default is
Air

Float

1.4

7522 7523

IDM_CONSTGC

W2

Gc Gas Constant: must be non-zero, default
is Air

Float

32.2

7524 7525

IDM_CONSTZ

W2

Z Gas Constant: must be non-zero, default is
Air

Float

1

7526 7527

IDM_FLOWOFFSET

W4

Measured Flow Offset: range -1400 to 1400

Float

0

7528 7529

IDM_SUPPRESOFF

W4

Supply Pressure Offset: (obsolete)

Float

0

7530 7531

IDM_TEMPOFF

W4

Gas Temp Sensor Offset: range -39.2 to 39.2
Deg F

Float

0

7532 7533

IDM_SONSUBHYS

W4

Subsonic/Subsonic Hysteresis.
Range -0.1 – 0.1

Float

0.03

7534 7535

IDM_DELTAPRESOFF

W4

Not used

Float

0

7536 7537

IDM_FLOWRANGE

W2

Flow Measurement and Control Max Limit:
range 1.0 – 20000.0 PPH

Float

1600

7538 7539

IDM_MAXSTROKE

W2

Maximum Stroke: range 0.005 – 0.275 in

Float

0.25

7540 7541

IDM_MAXVELOCITY

W4

Maximum Velocity: range 0.0 – 0.01

Float

0.0006

25

7542 7543

IDM_KP

W4

Position Control Proportional Constant: must
be non-zero

Float

0.038

7574 7545

IDM_KI

W4

Position Control Integral Constant: range 0.0
to 0.0156

Float

0.001

7576 7547

IDM_INPRESGAIN

W4

Input Pressure Sensor Gain: range 1 – 2

Float

1

15