Hamilton Sundstrand Company Fuel Metering Valves XVG User Manual

Page 16

Advertising
background image

Register
Number

XVG/eXVG Parameter

Name

Write

Access

Description Type

Default

Value

7578 7579

IDM_INPRESOFF

W4

Input Pressure Sensor Offset: range -10 – 10
PSIA

Float

0

7580 7581

IDM_OUTPRESGAIN

W4

Output Pressure Sensor Gain: range 1 – 2

Float

1

7582 7583

IDM_OUTPRESOFF

W4

Output Pressure Sensor Offset: range -10 –
10 PSIA

Float

0

7584 7585

IDM_TEMPSENSEGAIN

W4

Gas Temp Sensor Gain: range 0.1 – 3.0

Float

1

7586 7587

IDM_TEMPSENSEOFF

W4

Gas Temp Sensor Offset: -20 – 20 Deg F

Float

0

7588 7589

IDM_VOLTS3GAIN3

W4

3.3V Supply ADC Channel Gain: range 0.95
– 1.05

Float

1

7590 7591

IDM_VOLTS3OFF3

W4

3.3V Supply ADC Channel Offset: range -80
– 80 Counts

Float

0

7592 7593

IDM_CURSENSEGAIN

W4

Current Sense Gain: range 0.95 – 1.05

Float

1

7594 7595

IDM_CURSENSEOFF

W4

Current Sense Offset: range -80 – 80 counts

Float

0

7596 7597

IDM_OUTPUTOFF

W4

Feedback Output Offset: (Obsolete)

Float

0

7598 7599

IDM_TEMPCOMPFCT

W4

Temp Compensation Factor: range -1 – 1

Float

0.0000

33

7600 7601

IDM_MINIPFLOWCTRL

W4

Minimum Input Pressure to Enable Flow
Control Operation: range 5-450 PSIA

Float

20

7602 7603

IDM_AUTOZEROTOL

W4

Auto Zero Tolerance: must be non-zero,
0.030 max

Float

0.005

7604 7605

IDM_DMDVOLTGAIN

W4

Demand voltage gain, obsolete

Float

1

7606 7607

IDM_DMDVOLTOFF

W4

Demand voltage offset, obsolete

Float

0

7608 7609

IDM_AI0CURGAIN

W4

AI0 Current Gain: range 0.99 – 1.09

Float

1

7610 7611

IDM_AI0CUROFF

W4

AI0 Current Offset: range -(122.6 to 146.6)

Float

0

7612 7613

IDM_AI1CURGAIN

W4

AI1 Current Gain: range same as AI0

Float

1

7614 7615

IDM_AI1CUROFF

W4

AI1 Current Offset: range same as AI0

Float

0

7616 7617

IDM_AI2CURGAIN

W4

AI2 Current Gain: range same as AI0

Float

1

7618 7619

IDM_AI2CUROFF

W4

AI2 Current Offset: range same as AI0

Float

0

7620 7621

IDM_AI3CURGAIN

W4

AI3 Current Gain: range same as AI0

Float

1

7622 7623

IDM_AI3CUROFF

W4

AI3 Current Offset: range same as AI0

Float

0

7624 7625

IDM_AI4CURGAIN

W4

AI4 Current Gain: range same as AI0

Float

1

7626 7627

IDM_AI4CUROFF

W4

AI4 Current Offset: range same as AI0

Float

0

7628 7629

IDM_AI5CURGAIN

W4

AI5 Current Gain: range same as AI0

Float

1

7630 7631

IDM_AI5CUROFF

W4

AI5 Current Offset: range same as AI0

Float

0

7632 7633

IDM_OUTPCORX3

W4

Outlet pressure correction coefficient 3

Float

10000

7634 7635

IDM_OUTPCORX2

W4

Outlet pressure correction coefficient 2

Float

-6800

7636 7637

IDM_OUTPCORX1

W4

Outlet pressure correction coefficient 1

Float

1500

7638 7639

IDM_OUTPCORDIV

W4

Outlet pressure correction divisor

Float

8000

7640 7641

IDM_ADCINPRESGAIN

W4

Input Pressure Gain: range 0.97 – 1.03

Float

1

7642 7643

IDM_ADCINPRESOFF

W4

Input Pressure Offset: range -(122.6 to 146.6)

Float

0

7644 7645

IDM_ADCOUTPRESGAI
N

W4

Output Pressure Gain: range 0.97 – 1.03

Float

1

7646 7647

IDM_ADCOUTPRESOFF

W4

Output Pressure Offset: range -(122.6 to
146.6)

Float 0

7648 7649

IDM_AO0CURGAIN

W4

AO0 Current Gain: range 0.72 – 0.80

Float

1

16

Advertising
This manual is related to the following products: