XVG/eXVG Parameters
Name

Write

Access

Description Type

3099 IDM_TESTSTR[0]

3100 IDM_TESTSTR[1]

3101 IDM_TESTSTR[2]

3102 IDM_TESTSTR[3]

3103 IDM_TESTSTR[4]

3104 IDM_TESTSTR[5]

3105 IDM_TESTSTR[6]

3106 IDM_TESTSTR[7]

3107 IDM_TESTSTR[8]

3108 IDM_TESTSTR[9]

3109 IDM_TESTSTR[10]

3110 IDM_TESTSTR[11]

3111 IDM_TESTSTR[12]

3112 IDM_TESTSTR[13]

3113 IDM_TESTSTR[14]

3114 IDM_TESTSTR[15]

W0

Test string, used for Modbus write access password.
IDM_TESTSTR is an ASCII string array with
maximum of 16 elements. The string start at register
3099 and a Null (0) character is required to end the
string. Example: To enter PASSWORD, write:

80 to register 3099
65 to register 3100
83 to register 3101
83 to register 3102
87 to register 3103
79 to register 3104
82 to register 3105
68 to register 3106
0 to register 3107

ASCII

3115

IDM_AO0CHCFG

W2

Analog output channel 0 electrical configuration
selector. Can be used to automatically set output
configuration. Sets parameters when value assigned in
setup state. (Parameter is not stored in EEPROM.)
Returns configuration code when read is commanded.
0 = 4to20mA, 1 = 0to5V, 2 = 1to5V, 3 = 0to-5V.
When reading, an invalid setup returns “99”. An
invalid write returns SETUPERROR = 9001.

U16

3116

IDM_AO1CHCFG

W2

Analog output channel 1 electrical configuration
selector. Can be used to automatically set output
configuration. Sets parameters when value assigned in
setup state. (Parameter is not stored in EEPROM.)
Returns configuration code when read is commanded.
0 = 4to20mA, 1 = 0to5V, 2 = 1to5V, 3 = 0to-5V.
When reading, an invalid setup returns “99”. An
invalid write returns SETUPERROR = 9002.

U16

3117

IDM_AI0CHCFG

W2

Analog input channel 0 electrical configuration
selector. Can be used to automatically set input
configuration. Sets parameters when value assigned in
setup state. (Parameter is not stored in EEPROM.)
Returns configuration code when read is commanded.
0 = 4to20mA, 1 = 0to5V, 2 = 1to5V. When reading,
an invalid setup returns “99”. An invalid write returns
SETUPERROR = 9003.

U16

5000 5001

IDM_POSMANSTPT

RO

Not used, SW test parameter

U32

5002 5003

IDM_CURMANSTPT

RO

Not used, SW test parameter

U32

5004 5055

IDM_VALVEDMD

RO

Position Demand, counts 683-3413

U32

5006 5007

IDM_VALVESTATUS

RO

Position Status, counts 683-3413

U32

5008 5009

IDM_FVALVEDMD

RO

Fault Report Variable, not used

U32

5010 5011

IDM_FVALVESTATUS

RO

Fault Report Variable, not used

U32

5012 5013

IDM_FDATE

RO

Fault Report Variable, not used

U32

28