3 stroke position parameters, 4 pressure ratio parameters, Stroke position parameters – Hamilton Sundstrand Company Fuel Metering Valves XVG User Manual

Page 19: Pressure ratio parameters

Advertising
background image

Register
Number

XVG/eXVG Parameter

Name

Write

Access

Corresponding Demand

Type

Pre-

Cal

Default

5670 5671

IDM_POSTBL35

W2

Counts: 2218.6250, 13.0mA Demand

U32

567968

5672 5673

IDM_POSTBL36

W2

Counts: 2389.2500, 14.0mA Demand

U32

611648

5674 5675

IDM_POSTBL37

W2

Counts: 2559.8750, 15.0mA Demand

U32

655328

5676 5677

IDM_POSTBL38

W2

Counts: 2730.5000, 16.0mA Demand

U32

699008

5678 5679

IDM_POSTBL39

W2

Counts: 2901.1250, 17.0mA Demand

U32

742688

5680 5681

IDM_POSTBL40

W2

Counts: 3071.7500, 18.0mA Demand

U32

786368

5682 5683

IDM_POSTBL41

W2

Counts: 3242.3750, 19.0mA Demand

U32

830048

5684 5685

IDM_POSTBL42

W2

Counts: 3413.0000, 20.0mA Demand

U32

873728

Table 17: Position Interpolation Table Parameters


9.1.3 Stroke Position Parameters

For XVG/eXVG low measurement and flow control accuracy improvement, the CdA
values are calculated based not only stroke position (using stroke- CdA interpolation
table) but also on pressure ratio condition.
The following Stroke Position Table lists default values of fifteen stroke positions that
will be used in CdA values calculation. Table values are (stroke value*2

24

).


Register
Number

XVG/eXVG Parameter

Name

Write

Access

Corresponding Stroke

Type

Default

Value

5900 5901

IDM_STROKETBL0

W4

0.005

U32

83886

5902 5903

IDM_STROKETBL1

W4

0.01 U32

167772

5904 5905

IDM_STROKETBL2

W4

0.015 U32

251658

5906 5907

IDM_STROKETBL3

W4

0.03 U32

503316

5908 5909

IDM_STROKETBL4

W4

0.045 U32

754975

5910 5911

IDM_STROKETBL5

W4

0.0625 U32

1048576

5912 5913

IDM_STROKETBL6

W4

0.078125 U32

1310720

5914 5915

IDM_STROKETBL7

W4

0.09 U32

2097152

5916 5917

IDM_STROKETBL8

W4

0.1 U32

2621440

5918 5919

IDM_STROKETBL9

W4

0.125 U32

2936013

5920 5921

IDM_STROKETBL10

W4

0.15625 U32

3355443

5922 5923

IDM_STROKETBL11

W4

0.175 U32

3774874

5924 5925

IDM_STROKETBL12

W4

0.2 U32

4194304

5926 5927

IDM_STROKETBL13

W4

0.225 U32

4194472

5928 5929

IDM_STROKETBL14

W4

0.25 U32

4194640

Table 18: Stroke Position Table Parameters



9.1.4 Pressure Ratio Parameters

These pressure ratio values are used in calculation of CdA values based on stroke and
pressure ratio conditions. Table values are (pressure ratio value*2

24

).

19

Advertising