6 flow limiting mode parameters, Flow limiting mode parameters – Hamilton Sundstrand Company Fuel Metering Valves XVG User Manual

Page 23

Advertising
background image

Register
Number

XVG/eXVG Parameter

Name

Write

Access

Corresponding CdA value

Type

Default

Value

6238 6239

IDM_CDATBLPR7S14

W4

0.618915975 U32

10383687

6240 6241

IDM_CDATBLPR8S0

W4

0.017536998 U32

294222

6242 6243

IDM_CDATBLPR8S1

W4

0.034340978 U32

576146

6244 6245

IDM_CDATBLPR8S2

W4

0.045249999 U32

759169

6246 6247

IDM_CDATBLPR8S3

W4

0.075426996 U32

1265455

6248 6249

IDM_CDATBLPR8S4

W4

0.11294198 U32

1894852

6250 6251

IDM_CDATBLPR8S5

W4

0.154013991 U32

2583926

6252 6253

IDM_CDATBLPR8S6

W4

0.191594005 U32

3214414

6254 6255

IDM_CDATBLPR8S7

W4

0.233344972 U32

3914879

6256 6257

IDM_CDATBLPR8S8

W4

0.258821011 U32

4342296

6258 6259

IDM_CDATBLPR8S9

W4

0.302787006 U32

5079923

6260 6261

IDM_CDATBLPR8S10

W4

0.367821991 U32

6171029

6262 6263

IDM_CDATBLPR8S11

W4

0.415814996 U32

6976218

6264 6265

IDM_CDATBLPR8S12

W4

0.473388016 U32

7942133

6266 6267

IDM_CDATBLPR8S13

W4

0.527272999 U32

8846173

6268 6269

IDM_CDATBLPR8S14

W4

0.584348023 U32

9803733

6270 6271

IDM_CDATBLPR9S0

W4

0.017027974 U32

285682

6272 6273

IDM_CDATBLPR9S1

W4

0.033367991 U32

559822

6274 6275

IDM_CDATBLPR9S2

W4

0.043686986 U32

732946

6276 6267

IDM_CDATBLPR9S3

W4

0.073494017 U32

1233025

6278 6269

IDM_CDATBLPR9S4

W4

0.107271016 U32

1799709

6280 6281

IDM_CDATBLPR9S5

W4

0.150669992 U32

2527823

6282 6283

IDM_CDATBLPR9S6

W4

0.183247983 U32

3074391

6284 6285

IDM_CDATBLPR9S7

W4

0.231404006 U32

3882315

6286 6287

IDM_CDATBLPR9S8

W4

0.25821501 U32

4332129

6288 6289

IDM_CDATBLPR9S9

W4

0.281709015 U32

4726293

6290 6291

IDM_CDATBLPR9S10

W4

0.344421983 U32

5778442

6292 6293

IDM_CDATBLPR9S11

W4

0.391855001 U32

6574236

6294 6295

IDM_CDATBLPR9S12

W4

0.445888996 U32

7480776

6296 6297

IDM_CDATBLPR9S13

W4

0.501824021 U32

8419210

6298 6299

IDM_CDATBLPR9S14

W4

0.544903994 U32

9141972

Table 20: CdA-Pressure Ratio Table Parameters


9.1.6 Flow Limiting Mode Parameters

The following table is used to define the Flow Limiting Mode schedule. The 5-point
Flow Limiting Mode Table defines the minimum and maximum flow limits by
interpolation for a particular backpressure.

Valid Flow Limiting Mode Table Backpressure values are in the range 0.0 - 498.0, 32 bit
floating point format. Valid Flow Limiting Mode Table Minimum Flow values are in the
range 0.0 - 20000.0, 32 bit floating point format. Valid Flow Limiting Mode Table
Maximum Flow values are in the range 0.0 - 20000.0, 32 bit floating point format.