2 real time parameters, Real time parameters – Hamilton Sundstrand Company Fuel Metering Valves XVG User Manual

Page 24

Advertising
background image

Register
Number

XVG/eXVG Parameter

Name

Write

Access

Description Type

Default

Value

7544 7545

IDM_BACKPRES0

W2

Backpressure 0

Float

14.7

7546 7547

IDM_BACKPRES1

W2

Backpressure 1

Float

64.7

7548 7549

IDM_BACKPRES2

W2

Backpressure 2

Float

114.7

7550 7551

IDM_BACKPRES3

W2

Backpressure 3

Float

164.7

7552 7553

IDM_BACKPRES4

W2

Backpressure 4

Float

214.7

7554 7555

IDM_MINFLOWLIM0

W2

Minimum Flow 0

Float

0

7556 7557

IDM_MINFLOWLIM1

W2

Minimum Flow 1

Float

200

7558 7559

IDM_MINFLOWLIM2

W2

Minimum Flow 2

Float

500

7560 7561

IDM_MINFLOWLIM3

W2

Minimum Flow 3

Float

750

7562 7563

IDM_MINFLOWLIM4

W2

Minimum Flow 4

Float

1000

7564 7565

IDM_MAXFLOWLIM0

W2

Maximum Flow 0

Float

500

7566 7567

IDM_MAXFLOWLIM1

W2

Maximum Flow 1

Float

1500

7568 7569

IDM_MAXFLOWLIM2

W2

Maximum Flow 2

Float

3000

7570 7571

IDM_MAXFLOWLIM3

W2

Maximum Flow 3

Float

4500

7572 7573

IDM_MAXFLOWLIM4

W2

Maximum Flow 4

Float

6000

Table 21: Flow Limiting Mode Table Parameters

9.2 Real Time Parameters


Real time parameters are status parameters that show the operation status of the
XVG/eXVG. Most of the real time parameters are read-only.

Register
Number

XVG/eXVG Parameters
Name

Write

Access

Description Type

3000 IDM_DIGDEMAND

W0

Valve Demand in Digital Command Mode, range 683-
3413 counts

U16

3001 IDM_DIGSTATUS

RO

Valve Feedback in Digital Command Mode, range
683-3413 counts

U16

3002 IDM_STATE

RO

Valve State: 0=Setup, 1=Run, 2=Shutdown,
3=Calibration

U16

3003

IDM_SETUPVALID

RO

Setup Checksum Valid: 0=No, 1=Yes

U16

3004 IDM_FLOWCOND

RO

Flow Condition: 0=Sonic, 1=Subsonic, 2=Reverse
Flow

U16

3005 IDM_SETUPCONNECT

RO

Setup Mode: 1=Set Valve in Setup State, 2=Exit Setup
and Reset CPU

U16

3006

IDM_MEASFLOWCTS

RO

Measured Flow Counts, Range 0 – 4095

U16

3007

IDM_MEASFLOW3413

RO

Measured Flow Counts, Range 683 – 3413

U16

3008

IDM_RUNTMSECS

RO

Seconds elapsed since power on

U16

3009

IDM_RUNTMMINS

RO

Minutes elapsed since power on

U16

3010

IDM_SOLDUTYCYC

RO

Solenoid Duty Cycle, not used

U16

3011 IDM_UPDATEPID

RO Not

used

U16

3012

IDM_ADCCALADC

RO

ADC A 0.22V ref calibration counts 0 – 4095

U16

3013

IDM_ADC3VOLTS3

RO

3.3V Supply counts, range 0 – 4095

U16

24