2 accessing fault records procedure, Accessing fault records procedure – Hamilton Sundstrand Company Fuel Metering Valves XVG User Manual

Page 33

Advertising
background image

All XVG/eXVG parameters can be uploaded using Modbus Read Registers
function then convert the results into appropriate number representation for display
and monitoring. Model number and part number need to be converted into ASCII
character string. All registers are readable, choose whichever parameters are of
interest and read them.

10.2 Accessing Fault Records Procedure

The following parameters will be used to retrieve the XVG/eXVG fault records.
There are a maximum of 16 records available in the valve. The first eight are
permanent records, the other records are updated on a first-in first-out basis. When
there were 16 fault records in the valve, the oldest non-permanent record will be
deleted when a new fault record is created.

Register
Number

XVG/eXVG Parameter Name

Description

Type

Write

Access

3028

IDM_FRUNTMMINS

Fault Log, Run Time Minutes of fault log

U16

RO

3029

IDM_FRUNTMSECS

Fault Log, Run Time Seconds of fault log

U16

RO

3043

IDM_FRECORDNO

Fault Log Record No, selects fault log record, 0-
16

U16

W0

3044

IDM_FFAULTCODE

Fault Log, Fault Code of fault log record

U16

RO

3045

IDM_FRECORDS

Fault Log, Number of faults in fault log record

U16

RO

3094

IDM_TESTCTRL

Use to trigger EEPROM tasks (sets bits in
ETFLAGS). Fully functional using PECC
protocol. Using Modbus, only fault read task
allowed. See ETFLAGS for bits.

U16

W0

5026

IDM_FTOTALHRS

Fault Log, Total Hours of fault log record

U32

RO

5028

IDM_FRUNTMHRS

Fault Log, Run Time Hours of fault log

U32

RO

7050

IDM_FVOLTS3PT3

Fault Log, Volts3pt3 at time of fault

Float

RO

7052

IDM_FSOLTEMP

Fault report variable, not used

Float

RO

7054

IDM_FINPUTPRES

Fault Log, InputPres at time of fault

Float

RO

7056 IDM_FOUTPUTPRES

Fault

Log,

OutputPres at time of fault

Float

RO

7058

IDM_FGASTEMP

Fault Log, GasTemp at time of fault

Float

RO

7060

IDM_FFLOWRANGE

Fault report variable, not used

Float

RO

7062

IDM_FMEASFLOW

Fault Log, MeasFlow at time of fault

Float

RO

7064

IDM_FFAULTDATA

Fault Log, Fault Data at time of fault

Float

RO

7066

IDM_FPOSININCHES

Fault Log, PosInInches at time of fault

Float

RO

7068

IDM_FTEMPAMB

Fault Log, TempAmb at time of fault

Float

RO

7070

IDM_FVOLTSPOS15

Fault Log, VoltsPos15 at time of fault

Float

RO

7072

IDM_FVOLTSNEG15

Fault Log, VoltsNeg15 at time of fault

Float

RO

Table 24: Fault Records Parameters


33