1 quick start cables – Paradise RA 5785 User Manual

Page 24

Advertising
background image

24

208143 REV -

Operations Manual, HPA3, Mini Compact Outdoor SSPA

3.1 Quick Start Cables


For convenience all units ship with a ‘Quick-Start’ communications cable. This allows the user
to immediately connect the amplifier to a PC and begin operation. Units ship with a Quick
Start cable fitted with a 10-base T connector as shown in Figure 3-5.

Figure 3-3: J4 Connections for RS-485 Communications

Chassis Ground

TX Enable

Interface Select 0

Interface Select 1

RS232/RS485 Select

Isolated Return for RS232/RS485

RS485 (RX-) RS232 (RX)

RS485 (TX-) RS232 (TX)

RS485 (TX+)

RS485 (RX+)

V

B

e

j

D

d

F

E

T

U

J4

Figure 3-4: J4 Connections for RS-232 Communications

Chassis Ground

TX Enable

Interface Select 0

Interface Select 1

RS232/RS485 Select

Isolated Return for RS232/RS485

RS232 (RX)

RS232 (TX)

V

B

e

j

D

d

F

E

J4

Figure 3-5: Ethernet Quick Start Cable, 207755 (Revision A and beyond)