Table 8-7: system settings data values – Paradise RA 5785 User Manual

Page 67

Advertising
background image

Operations Manual, HPA3, Mini Compact Outdoor SSPA

208143 REV -

67

Table 8-7: System Settings Data Values

Data

Address

# Bytes

Description

Limits and Byte Values

1

1

System Operation Mode

Single Amplifier = 255

1:1 Redundant = 0

2

1

System Hierarchical Address

Unit 1= 0; Unit 2= 255

3 1

Unit Start Up State

(in Redundancy)

On Line Amplifier = 255

Standby Amplifier = 0

4

1

Mute State

Mute Clear (Transmit Enable) = 255

Mute Set (Transmit Disable) = 0

5 1

Attenuation Level

(dB down from maximum gain)

[1 bit for every 0.1 dB]

0 dB attenuation = 0

20 dB attenuation = 200

6

1

RESERVE

N/A

7

1

Amplifier Network Address

1 to 255

8

1

High Temperature Alarm Threshold

0 to 100 (in

o

C)

9

1

SSPA module Calibration Mode

Temperature Compensated = 255 (normal state)

Tune Mode = 1 (Factory Use Only)

Calibration Mode = 0 (Factory Use Only)

10

1

SSPA Spare Fault Status

Ignore Spare Fault = 255

Fault on value of window on ADC channel = 0 to 1

Fault on External Mute = 8

11

1

SSPA Spare Fault Handling

Minor Fault (no effect on Summary Fault) = 255

Major Fault (Triggers Summary Fault) = 0

Major Fault with Mute (Transmit Disabled) = 1

12

1

Auxiliary Fault Status

Disabled = 255

Fault High = 0

Fault Low = 1

13

1

Auxiliary Fault Handling

Minor Fault (no effect on Summary Fault) = 255

Major Fault (Triggers Summary Fault) = 0

Major Fault with Mute (Transmit Disabled) = 1

14

1

BUC Fault Status

Enabled = 0

Disabled = 255

15

1

BUC Fault Handling

Minor Fault (no effect on Summary Fault) = 255

Major Fault (Triggers Summary Fault) =0

Major Fault with Mute (Transmit Disabled) = 1

16

1

Protocol Select

Serial = 255

IPNET (Ethernet UDP, Web M&C) = 3

SNMP = 4

17

1

Baud Rate Select

9600 = 255

38400 = 0
19200 = 1

4800 = 2
2400 = 3

18

1

Fiber Optic Fault Status

Disabled = 255

Fault on Logic High = 0

Fault on Logic Low = 1

19

1

Fiber Optic Fault Handling

Minor Fault (no effect on Summary Fault) = 255

Major Fault (Triggers Summary Fault) =0

Major Fault with Mute (Transmit Disabled) = 1

20

1

Standby Mode

Hot standby=255; Cold standby=0

(continued)

21

1

BUC Reference

Autoswitch = 0; External = 1; Internal = 2

22

1

Forward RF Fault Status

Disabled = 255

Low RF Fault Threshold = 0

RF Window @ 10% = 1
RF Window @ 15% = 2

High RF Threshold = 3

Note: Data length must be at least two bytes to form integer with the lower byte sent first. If an odd number of bytes is received, the last byte