Operations Manual, HPA3, Mini Compact Outdoor SSPA

208143 REV -

69

Table 8-9: System Condition Addressing

Data

Address

# Bytes

Description

Limits and valid values

1 2

Attenuation DAC value

(Read Only in Temp Co Mode)

0 to 4095

2

2

Present Temperature

+/- 100

3

2

Fault, Mute, and State Conditions

2-Byte Value

0 fault clear; 1 fault set

0 mute clear; 1 mute set

0 standby state, 1 on line state

0 Ext. Ref, 1 Internal Ref

Lower Byte

Bit 0 = Summary Fault
Bit 1 = High Temp Fault
Bit 2 = Low DC Current Fault
Bit 3 = Low DC Voltage Fault
Bit 4 = External Mute Status
Bit 5 = Internal Mute Status
Bit 6 = Forward RF Fault
Bit 7 = Reference Source

High Byte

Bit 0 = BUC Fault
Bit 1 = Spare Fault
Bit 2 = Auxiliary Fault
Bit 3 = Fiber Fault
Bit 4 = RF Switch Control 1 state
Bit 5 = RF Switch Control 2 state
Bit 6 = Reserved, Always 0
Bit 7 = Unit On Line State

4

2

Present Attenuation Level

1bit per 0.1 dB attenuation

Low Byte: 0 to 150

High Byte: always 0

5 2

Present RF Power Level

Output is dBm x 10

0 to 800

6

2

Total DC Current

20 Amp maximum
1 value = 0.1 Amp

7

2

PS2 Regulator DC Voltage

15 Volt maximum
1 value = 0.1 Volt

8

2

PS2 Voltage

15 Volt maximum
1 value = 0.1 Volt

9

2

Transistor Gate Voltage

0 to 10 volt range

Use 2’s compliment integer math

1 value = 0.1 Volt

10

2

PS1 DC Current

1Value = 0.1 Volt

11

2

PS1 Regulator DC Voltage

1Value = 0.1 Volt

12

2

PS1 Voltage

1Value = 0.1V

13

2

External Reference Level

0 to 1023

14

2

Baseplate Temperature

+/- 100

15 2

Tempco DAC value

(Read Only in Temp Co Mode)

0 to 4095

Note: Data length must be at least two bytes to form integer with the lower byte sent first. If odd number of bytes is received, the
last byte will be saved as the lower byte of the integer and upper part will be zero.