Operations Manual, HPA3, Mini Compact Outdoor SSPA

208143 REV -

33

rate is 9600. You will be asked to verify that you wish to change the Baud
Rate. Communication with the amplifier may be affected.

[

7

]

Standby Mode: Selects between Hot and Cold standby mode for units in

redundant systems.

[

8

]

BUC Reference: Selects between an Internal or External reference for an

optional block up coverter integrated with the unit, or allows the unit to Auto-
switch between Internal and External reference.

[

9

]

Attenuation Level: The Gain Adjustment of the unit is adjustable here, from

0 to 20 in 0.1 db steps.

[

10

]

Amplifier Network Address: Sets a network address for the unit. Range

is 0 to 255. You will be asked to verify that you wish to change the
Amplifier Network Address. Communication with the amplifier may be
affected.

[

11

]

Fault Thresholds: Allows the user to set the limit for triggering the unit’s

Current Fault or High Temperature Fault.

Low Current Fault Threshold: This setting is factory pre-set.
High Temperature Alarm Threshold: Range is 0 to 125 °C.

[

12

]

Fault Setup: This feature allows the user to set the Spare Fault Trigger

using the Spare Fault Wizard.

Click on the Spare Fault Wizard button, which opens a new window. See Figure
3-11
. Select between the following fault triggers: External Reference Level, LNB
Current, External Mute, or None. Set the range of maximum and minimum
thresholds that would trigger the selected fault, and configure the fault handling
via a pull-down menu. Choose between Major Fault, Major Fault with Mute, and
Minor Fault. Click [OK] to set the fault trigger for the Spare Fault.

Figure 3-11: Spare Fault Wizard