Testing

5-2

7510-A2-GB20-00

March 1997

Loopbacks can be started from a variety of points in the network, as shown in
Table 5-1.

Table 5-1.

Device Messages

Loopback Type

Initiated By

Notes

Bilateral Loopback

H

User

H

Remote unit sending
V.54 sequence

When enabled, running a DSU loopback
also automatically starts a local
loopback. Refer to

Data Port Options

,

Table A-3, to enable.

CSU Loopback

H

User (Network tests)

H

DDS Network, by
loop current reversal

When initiated by the network, CSU
Loopback cannot be disabled by the
user.

DSU Loopback
(Digital)

H

User

Refer to

Data Port Options

, Table A-3.

Local Loopback

H

User

H

DTE via CT141

Control via CT141 can be disabled.
Refer to

Data Port Options

, Table A-3.

Network-initiated
56 kbps DSU
Loopback (Non-
latching loopback)

H

DDS Network

Cannot be disabled by user.

Network-initiated
64 kbps CC DSU
Loopback
(Latching loopback)

H

DDS Network

Includes optional data scrambling and
uses 25-second timer to detect the
network sequence. Can be disabled by
user.

Remote Digital
Loopback

H

Remote unit sending
V.54 sequence

Same as a DSU Loopback but initiated
by a remote unit via V.54 sequence.
Can be disabled locally. Refer to

Network Interface Options

, Table A-2.

V.54 Sequences to
remote unit

H

User

H

DTE via CT140

Control via CT140 can be disabled.
Refer to

Data Port Options

, Table A-3.