Resetting the dsu, Displaying dsu identity information – Paradyne 7510-A2-GB20-00 727 User Manual

Page 47

Advertising
background image

Messages and Troubleshooting

6-4

7510-A2-GB20-00

March 1997

Table 6-2.

Troubleshooting (2 of 2)

Symptom

Solutions

Possible Cause

Not receiving data;
DSU is not
responding.

H

DDS line rate/speed has
changed.

H

Excessive BPVs causing
DSU to become stuck in
Autobaud mode.

H

Excessive Loop Loss
causing DSU to become
stuck in Autobaud mode.

1. Verify that your subscriber loop is

running at 56 or 64 CC kbps.

2. If getting Excessive BPVs, verify

that you do not have a bad cable.
If the cable is good, contact the
network provider.

3. If getting excessive Loop Loss

(dB) indications, install a higher
quality cable. Refer to

Table D-2

in Appendix D,

Model 7510

in Appendix D,

Model 7510

DSU LADS Connection
Distances

.

4. If the DDS Line Rate (Kbps) field

shows Autobaud, the DSU may
be stuck in Autobaud mode.
Configure Line Rate (Kbps) for
56 or 64 kbps.

5. Run Loopback tests. Refer to

Running Network Tests

in of

Chapter 5.

Power-Up Self-Test
fails. Only Alarm
LED is on after
power-up.

The DSU has detected an
internal hardware failure.

H

Reset the DSU and try again.

H

Contact your service
representative.

Resetting the DSU

The DSU can be reset locally or remotely.

To reset the DSU, follow this menu selection sequence:

Main Menu

Control

Reset Device

The DSU reinitializes itself, performing a Device Self-Test. Refer to

Self-Test

Results Messages

, Table 4-3.

Displaying DSU Identity Information

To display the DSU’s system name, location, contact, serial number, model
number, and software and hardware revision numbers, follow this menu selection
sequence:

Main Menu

Status

Identity