Local loopback, 511 test pattern for the dte – Paradyne 7510-A2-GB20-00 727 User Manual

Page 41

Advertising
background image

Testing

5-8

7510-A2-GB20-00

March 1997

Local Loopback

Local Loopback loops the user data back to the DTE. This loopback is located as
closely as possible to the User Data Port (DTE) interface.

"

Procedure

To run a local loopback:

1. Position the cursor at the Start command next to Local Loopback on the Data

Port Tests screen.

2. Press Enter.

3. The Start command is changed to Stop. If you want to manually stop the test,

verify that the cursor is positioned at the Stop command.

4. Press Enter. The duration of the test is displayed.

DSU

CSU

DTE

Interface

Aggregate

DDS
Network
Port

496-15145

DTE

Port

Local Loopback

511 Test Pattern for the DTE

This test sends or monitors a 511 test pattern over the User Data Port interface.

"

Procedure

To run a Send 511 test:

1. Position the cursor at the Start command next to Send 511 on the Data Port

Tests screen.

2. Press Enter.

3. The Start command is changed to Stop. If you want to manually stop the test,

verify that the cursor is positioned at the Stop command.

4. Press Enter. The duration of the test is displayed.