Troubleshooting – Paradyne 7510-A2-GB20-00 727 User Manual

Page 46

Advertising
background image

Messages and Troubleshooting

6-3

7510-A2-GB20-00

March 1997

Troubleshooting

This DSU is designed to provide you with many years of trouble-free service. If a
problem occurs, however, refer to Table 6-2 for

possible solutions.

Table 6-2.

Troubleshooting (1 of 2)

Symptom

Possible Cause

Solutions

Alarm LED is on.

One of several alarm
conditions exists. Health
and Status displays the
alarm condition.

Refer to

Health and Status

Messages

, Table 4-2, for

recommended action.

Cannot access the
DSU via the ATI.

The terminal is not set up
for the correct rate or data
format, or the DSU is
configured so it prevents
access.

1. Check the cable and

connections.

2. Set up your terminal or PC

emulation as shown in

Connecting to the Terminal Port

in Chapter 2.

3. Power the DSU on and off and

try again.

Device Fail appears
on the System and
Test Status screen
under Self-Test
results.

The DSU detects an
internal hardware failure.

H

Power the DSU off and on and
try again.

H

Contact your service
representative.

An LED is not lit.

LED is burned out.

Run the Lamp test. If the LED in
question does not flash with the
other LEDs, then contact your
service representative.

No power, or the
LEDs are not lit.

The power cord is not
securely plugged into the
wall receptacle and into the
rear panel connection.

Check that the power cord is
securely attached at both ends.

The wall receptacle has no
power.

H

Check the wall receptacle power
by plugging in some equipment
that is known to be working.

H

Check the circuit breaker.

H

Verify that your site is not on an
energy management program.

Power supply has failed.

Replace power supply.

Advertising