3 rs-485, 4 alarm input and alarm output, Rs-485 – Planet Technology 23x Indoor Speed Dome Camera CAM-ISD48 User Manual

Page 28: Alarm input and alarm output

Advertising
background image

6.3 RS-485

The camera adapts RS-485 in half-duplex pattern, which

is a two-pin connectivity, as shown on the right picture.

Installer must pay attention to the polarity of these two

pins – yellow wire is the POSITIVE end, and orange is the

NEGATIVE. Communication between controller and

camera will break and control will not function if they are

reversely connected.

The RS-485 communication may run for 4,000 feet if the system network is properly

built. Two important factors should be handled with care during the system

build-up--- baud rate and termination impedance. More information about RS-485

are in sections “Protocol and Baud rate” and “Applications”.

6.4 Alarm Input and Alarm Output

This camera is equipped with 3 alarm inputs and one alarm output for intrusion
management. Installers may connect the inputs to the various sensors and program
the camera to move and monitor specific spots for monitoring when evens take
place. Dwell time for monitoring is programmable, subject to the system. Refer to
the diagram on right for function assignments of the alarm I/O.

Alarm in

Wire Color

Alarm GND

Wire Color

Alarm out

Wire Color

Alarm in 1

Black

Alarm 1

Brown

N.O.

Gray

Alarm in 2

Red

Alarm 2

Orange

N.C.

Purple

Alarm in 3

Yellow

Alarm 3

Green

Com.

Blue


Alarm inputs

This speed dome has three alarm inputs, and each input is given by the software a
companion view preset. When trigger single is sent to alarm-in, the following
reactions will be taken by the speed dome:

„

The pan-tilt mechanism will move lens to the preset.

„

The alarm-out port will act.

„

Via RS-485, the console (control unit) will be notified

.

.

User’s manual

28

Advertising