18. Liquid Propane Hook-Up

Attach the regulator (A) to the propane cylinder (B) by
turning the regulator handle clockwise as shown in fig.
20. If the outdoor cooking appliance is not in use, the
gas must be turned “OFF” at the Liquid Propane cylinder.


Check all gas supply fittings for leaks before each
use. Do not use the grill until all connections have
been checked and do not leak
(see “Leak Testing”
instructions on page 16).


INSTALLATION INSTRUCTIONS

GAS HOOK-UP

Only the pressure regulator and hose assembly supplied with the grill should be used. Any replacement
pressure regulator and hose assembly must be specified by the grill manufacturer.

This grill is configured for Liquid Propane. Do not use a Natural Gas supply.

Total gas consumption (per hour) of the 720-0522 Liquid Propane gas grill with all burners set on “HI”:
Main burners 50,000 BTU/Hr.
Rear burner

10,000 BTU/Hr.

Side burner

15,000 BTU/Hr.

Total

75,000 BTU/Hr.


The installation of this appliance must conform with local codes or, in the absence of local codes, with
either the National Fuel Gas Code, ANSI Z223.1/NFPA 54, National Gas Propane Installation Code, CSA
B149.2.
Installation in Canada must be in accordance with the Standard CAN/CGA-B149.2 (installation code for
gas burning appliances and equipment) and local codes.


LIQUID PROPANE CYLINDER REQUIREMENTS
(20-lb Cylinder)
A dented or rusty Liquid Propane cylinder may be hazardous and should be checked by your supplier.
Never use a cylinder with a damaged valve. The Liquid Propane cylinder must be constructed and
marked in accordance with the specifications for Liquid Propane cylinders by the United States
Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339, Cylinders,
Spheres and Tubes for Transportation of Dangerous Goods Commission.

The 20-lb cylinder must have a shut off valve terminating in a valve outlet specified, as applicable, for
connection type QCC1 in the standard for compressed gas cylinder valve outlet and inlet connection
ANSI/CGA-V-1.

Storage of an outdoor cooking gas appliance indoor is permissible only if the cylinder is disconnected and
removed from the outdoor cooking gas appliance. The cylinder system must be arranged for vapor
withdrawal. The cylinder must include a collar to protect the cylinder valve.

Manifold pressure: (operating) 10 inches water column (W.C.), (non-operating) 11.2 inches water column
(W.C.).

The Liquid Propane cylinder must be fitted with an Overfill Protection Device (OPD).